Why buy from us?
Because we are the best at Service Delivery
Ask a Question About This Product
Product Overview
Engineered for industrial automation, high-power LED installations, and precision embedded systems, the BDN Multi-Range AC-DC Regulated Switching Power Supply series delivers high-efficiency power conversion across 50W to 600W configurations. Designed to operate reliably under variable mains electrical conditions, this robust power platform features wide AC dual-voltage tolerance with low ripple, low noise, and integrated line filtering.
Key Specifications & Variant Matrix
Input Voltage Range: 100-240V AC universal or 110V/220V AC ±15% manual switchable selection (50/60Hz). Available DC Output Configurations: 5V DC at 10A (50W), 12V DC at 10A (120W), 12V DC at 15A (180W), and 12V DC at 50A (600W). Load Regulation: ±1.0%. Voltage Tolerance: ±1.0%. High conversion efficiency up to 88% nominal.
Available List of items
DC Output: 5V 10A (50W)
12V 10A (120W)
12V 15A (180W)
12V 50A (600W)
Integrated Hardware Protection
Each unit incorporates comprehensive multi-stage circuit defense including active output over-voltage clamping (OVP), foldback over-current protection (OCP), automatic-recovery short-circuit protection (SCP), and input surge suppression. Visual operational status is continuously indicated via a primary output LED diagnostic indicator.
Thermal & Mechanical Architecture
Constructed inside a perforated, corrosion-resistant aluminum mesh chassis optimized for passive convection airflow and rapid thermal dissipation. The heavy-duty terminal block array features protective safety covers and screw-clamp retention rated for continuous duty in demanding industrial and telecommunications deployments.
Target Applications
Ideal for high-density LED signage, machine vision systems, 3D printers, CNC control boards, industrial PLCs, telecommunication relays, and modular edge computing power distribution racks.
| PSC-60 UPS/Charge Function Switching Power Supply | |||||
| Project | Technical indicators | ||||
| Model | PSC-60-12 | PSC-60-24 | |||
| Output | DC voltage | CH1:13.8V | CH2:13.8V | CH1:27.6V | CH2 :27.6V |
| Output voltage tolerance |
±1% | ——– | ±1% | ——– | |
| Rated current | 3.5A | 1A(Charge) | 1.5A | 0.7A(Charge) | |
| Ripple and noise | 150mVp-p | ——- | 200mVp-p | ——– | |
| rated power | 60W | 60W | |||
| Output current range | 0-4.5A | ——– | 0-4.5A | ——- | |
| DC voltage adjustable range |
CH1:11.3-14.9V | CH1:21.3-29.8V | |||
| Start,rise,hold time | 600ms、50ms、80ms:230VAC , 1200ms、50ms、16ms:115VAC |
600ms、50ms、80ms:230VAC, 1200ms、50ms、16ms:115VAC |
|||
| Input | voltage range | 90-264VAC 47-63HZ;135VDC~370VDC | |||
| Efficiency(typical) | >88% | >88% | >88% | >88% | |
| Working current | 115VAC<1.8A ,230VAC <0.9A | ||||
| pulse current | 110VAC 25A,230VAC 40A | ||||
| Start,rise,hold time | 100ms、30ms、21ms:110VAC ,100ms、30ms、100ms: 220VAC |
||||
| Protect | Overload protection | When the output rated power is>105%-115%:Protection mode: hiccup mode,it can automatically recover after the abnormal conditions are removed. |
|||
| Battery low voltage protection |
9.5~10.3V,Protection mode,cut off output | 19~20.5V,Protection mode,cut off output | |||
| Environment | Working temperature, humidity |
-20C~+60°℃,20%~90RH | |||
| Storage temperature and humidity |
-20C~+85℃,10%~95RH | ||||
| Function | UPS | Long-term online float charging of the battery,high charging efficiency,battery fullness can be as high as 97% or more |
|||
| Automatically stops when fully charged to prevent battery overcharging and effectively extend battery life |
|||||
| Automatic mains/battery switching,no switching time,no need for human supervision. | |||||
| Cold start function,when there is no mains power,the UPS can be started directly with the battery to meet the user’s emergency needs |
|||||
| Safety regulations |
Protection mode,cut off output |
Input and output:1.5KVAC,1 minute | |||
| solation resistor | Input and output,input shell,output shell:500VDC/100MQ | ||||
| Other | size | 129*97*30mm | |||
| Net weight/gross weight | 0.38KG/0.42KG | ||||
| PSC-100 UPS/Charge Function Switching Power Supply | |||||
| Project | Technical indicators | ||||
| Model | PSC-100-12 | PSC-100-24 | |||
| Output | DC voltage | CH1:13.8V | CH2:13.8V | CH1:27.6V | CH2 :27.6V |
| Output voltage tolerance |
±1% | ——– | ±1% | ——– | |
| Rated current | 5A | 2A(Charge) | 2.5A | 1A(Charge) | |
| Ripple and noise | 150mVp-p | ——- | 200mVp-p | ——– | |
| rated power | 100W | 100W | |||
| Output current range | 0-7A | ——– | 0-3.5A | ——- | |
| DC voltage adjustable range |
CH1:11.3-14.9V | CH1:21.3-29.8V | |||
| Start,rise,hold time | 600ms、50ms、80ms:230VAC , 1200ms、50ms、16ms:115VAC |
600ms、50ms、80ms:230VAC, 1200ms、50ms、16ms:115VAC |
|||
| Input | voltage range | 90-264VAC 47-63HZ;135VDC~370VDC | |||
| Efficiency(typical) | >87% | >87% | >87% | >87% | |
| Working current | 115VAC<2.4A ,230VAC <1.2A | ||||
| pulse current | 110VAC 30A,230VAC 50A | ||||
| Start,rise,hold time | 100ms、30ms、21ms:110VAC ,100ms、30ms、100ms: 220VAC |
||||
| Protect | Overload protection | When the output rated power is>105%-115%:Protection mode: hiccup mode,it can automatically recover after the abnormal conditions are removed. |
|||
| Battery low voltage protection |
9.5~10.3V,Protection mode,cut off output | 19~20.5V,Protection mode,cut off output | |||
| Environment | Working temperature, humidity |
-20C~+60°℃,20%~90RH | |||
| Storage temperature and humidity |
-20C~+85℃,10%~95RH | ||||
| Function | UPS | Long-term online float charging of the battery,high charging efficiency,battery fullness can be as high as 97% or more |
|||
| Automatically stops when fully charged to prevent battery overcharging and effectively extend battery life |
|||||
| Automatic mains/battery switching,no switching time,no need for human supervision. | |||||
| Cold start function,when there is no mains power,the UPS can be started directly with the battery to meet the user’s emergency needs |
|||||
| Safety regulations |
Protection mode,cut off output |
Input and output:1.5KVAC,1 minute | |||
| solation resistor | Input and output,input shell,output shell:500VDC/100MQ | ||||
| Other | size | 129*97*30mm | |||
| Net weight/gross weight | 0.38KG/0.42KG | ||||
| PSC-150 UPS/Charge Function Switching Power Supply | |||||
| Project | Technical indicators | ||||
| Model | PSC-150-12 | PSC-150-24 | |||
| Output | DC voltage | CH1:13.8V | CH2:13.8V | CH1:27.6V | CH2 :27.6V |
| Output voltage tolerance |
±1% | ——– | ±1% | ——– | |
| Rated current | 7.5A | 3A(Charge) | 4A | 1.5A(Charge) | |
| Ripple and noise | 150mVp-p | ——- | 200mVp-p | ——– | |
| rated power | 150W | 152W | |||
| Output current range | 0-10.5A | ——– | 0-5.5A | ——- | |
| DC voltage adjustable range |
CH1:11.3-14.9V | CH1:21.3-29.8V | |||
| Start,rise,hold time | 600ms、50ms、80ms:230VAC , 1200ms、50ms、16ms:115VAC |
600ms、50ms、80ms:230VAC, 1200ms、50ms、16ms:115VAC |
|||
| Input | voltage range | 90-264VAC 47-63HZ;135VDC~370VDC | |||
| Efficiency(typical) | >87% | >87% | >89% | >89% | |
| Working current | 115VAC<3.2A ,230VAC <1.6A | ||||
| pulse current | 110VAC 30A,230VAC 50A | ||||
| Protect | Overload protection | When the output rated power is>105%-115%:Protection mode: hiccup mode,it can automatically recover after the abnormal conditions are removed. |
|||
| Battery low voltage protection |
9.5~10.3V,Protection mode,cut off output | 19~20.5V,Protection mode,cut off output | |||
| Environment | Working temperature, humidity |
-20C~+60°℃,20%~90RH | |||
| Storage temperature and humidity |
-20C~+85℃,10%~95RH | ||||
| Function | UPS | Long-term online float charging of the battery,high charging efficiency,battery fullness can be as high as 97% or more |
|||
| Automatically stops when fully charged to prevent battery overcharging and effectively extend battery life |
|||||
| Automatic mains/battery switching,no switching time,no need for human supervision. | |||||
| Cold start function,when there is no mains power,the UPS can be started directly with the battery to meet the user’s emergency needs |
|||||
| Safety regulations |
Protection mode,cut off output |
Input and output:1.5KVAC,1 minute | |||
| solation resistor | Input and output,input shell,output shell:500VDC/100MQ | ||||
| Other | size | 159*97*30mm | |||
| Net weight/gross weight | 0.47KG/0.55KG | ||||
| PSC-250 UPS/Charge Function Switching Power Supply | |||||
| Project | Technical indicators | ||||
| Model | PSC-250-12 | PSC-250-24 | |||
| Output | DC voltage | CH1:13.8V | CH2:13.8V | CH1:27.6V | CH2 :27.6V |
| Output voltage tolerance |
±1% | ——– | ±1% | ——– | |
| Rated current | 14.5A | 3.5A(Charge) | 6.5A | 2.5A(Charge) | |
| Ripple and noise | 150mVp-p | ——- | 200mVp-p | ——– | |
| rated power | 250W | 250W | |||
| Output current range | 0-18A | ——– | 0-9A | ——- | |
| DC voltage adjustable range |
CH1:11.3-14.9V | CH1:21.3-29.8V | |||
| Start,rise,hold time | 600ms、50ms、80ms:230VAC , 1200ms、50ms、16ms:115VAC |
600ms、50ms、80ms:230VAC, 1200ms、50ms、16ms:115VAC |
|||
| Input | voltage range | 90-264VAC 47-63HZ;135VDC~370VDC | |||
| Efficiency(typical) | >87% | >87% | >89% | >89% | |
| Working current | 115VAC<4.5A ,230VAC <2.5A | ||||
| pulse current | 110VAC 45A,230VAC 55A | ||||
| Protect | Overload protection | When the output rated power is>105%-115%:Protection mode: hiccup mode,it can automatically recover after the abnormal conditions are removed. |
|||
| Battery low voltage protection |
9.5~10.3V,Protection mode,cut off output | 19~20.5V,Protection mode,cut off output | |||
| Environment | Working temperature, humidity |
-20C~+60°℃,20%~90RH | |||
| Storage temperature and humidity |
-20C~+85℃,10%~95RH | ||||
| Function | UPS | Long-term online float charging of the battery,high charging efficiency,battery fullness can be as high as 97% or more |
|||
| Automatically stops when fully charged to prevent battery overcharging and effectively extend battery life |
|||||
| Automatic mains/battery switching,no switching time,no need for human supervision. | |||||
| Cold start function,when there is no mains power,the UPS can be started directly with the battery to meet the user’s emergency needs |
|||||
| Safety regulations |
Protection mode,cut off output |
Input and output:1.5KVAC,1 minute | |||
| solation resistor | Input and output,input shell,output shell:500VDC/100MQ | ||||
| Other | size | 215*115*30mm | |||
| Net weight/gross weight | 0.75KG/0.82KG | ||||
| PSC-350 UPS/Charge Function Switching Power Supply | |||||
| Project | Technical indicators | ||||
| Model | PSC-350-12 | PSC-350-24 | |||
| Output | DC voltage | CH1:13.8V | CH2:13.8V | CH1:27.6V | CH2 :27.6V |
| Output voltage tolerance |
±1% | ——– | ±1% | ——– | |
| Rated current | 20A | 5A(Charge) | 10A | 2.5A(Charge) | |
| Ripple and noise | 150mVp-p | ——- | 200mVp-p | ——– | |
| rated power | 345W | 350W | |||
| Output current range | 0-18A | ——– | 0-9A | ——- | |
| DC voltage adjustable range |
CH1:11.3-14.9V | CH1:21.3-29.8V | |||
| Start,rise,hold time | 600ms、50ms、80ms:230VAC , 1200ms、50ms、16ms:115VAC |
600ms、50ms、80ms:230VAC, 1200ms、50ms、16ms:115VAC |
|||
| Input | voltage range | 90-264VAC 47-63HZ;135VDC~370VDC | |||
| Efficiency(typical) | >87% | >87% | >89% | >89% | |
| Working current | 115VAC<6.5A ,230VAC <3.5A | ||||
| pulse current | 110VAC 45A,230VAC 55A | ||||
| Protect | Overload protection | When the output rated power is>105%-115%:Protection mode: hiccup mode,it can automatically recover after the abnormal conditions are removed. |
|||
| Battery low voltage protection |
9.5~10.3V,Protection mode,cut off output | 19~20.5V,Protection mode,cut off output | |||
| Environment | Working temperature, humidity |
-20C~+60°℃,20%~90RH | |||
| Storage temperature and humidity |
-20C~+85℃,10%~95RH | ||||
| Function | UPS | Long-term online float charging of the battery,high charging efficiency,battery fullness can be as high as 97% or more |
|||
| Automatically stops when fully charged to prevent battery overcharging and effectively extend battery life |
|||||
| Automatic mains/battery switching,no switching time,no need for human supervision. | |||||
| Cold start function,when there is no mains power,the UPS can be started directly with the battery to meet the user’s emergency needs |
|||||
| Safety regulations |
Protection mode,cut off output |
Input and output:1.5KVAC,1 minute | |||
| solation resistor | Input and output,input shell,output shell:500VDC/100MQ | ||||
| Other | size | 215*115*30mm | |||
| Net weight/gross weight | 0.85KG/0.95KG | ||||
- Stock: In Stock
- Model: Industrial Switching PSU
- Weight: 850.00g
- Dimensions: 215.00mm x 115.00mm x 50.00mm
- SKU: 49