System Architecture & Power Topology
The MDR-100-24 is an industrial-grade, single-phase switching power supply engineered to deliver high-efficiency conversion within high-density control cabinets. Featuring an ultra-wide universal input range of 85–264VAC (or 120–370VDC) and built-in active Power Factor Correction (PFC), the topology ensures stable operation under varying power conditions while minimizing harmonic line distortion. It delivers a nominal 24V DC output at up to 4.16A (100W continuous rating), maintaining exceptional regulation tolerances with linear and load adjustments tightly bounded within ±1%.
Chassis Dynamics & Material Engineering
Engineered with a low-profile 40mm enclosure, the unit optimizes horizontal DIN rail space in multi-tier control panels. The chassis is fabricated from high-grade, flame-retardant industrial polymer designed to resist elevated thermal stresses and chemical exposure. Internal thermal pathways utilize natural convection air cooling without requiring forced-air fans, mitigating mechanical failure points and sustaining silent, maintenance-free operation across harsh operational environments.
Protection Systems & Operational Endurance
Engineered to ensure zero-downtime industrial reliability, the internal electronics integrate multi-stage protection circuits. Output overload protection activates between 105% and 150% via auto-recovering hiccup mode, while overvoltage clamping engages at >135% to shield downstream instrumentation. Over-temperature detection circuits actively suppress thermal runaway. Electrical isolation meets stringent safety standards with withstand ratings of 3.0kVAC between input and output, 1.5kVAC input-to-ground, and 500VDC/100MΩ insulation resistance across structural boundaries.
Diagnostics & Industrial Deployment
The unit features integrated electromechanical DC OK dry relay contacts for remote telemetry, enabling PLC diagnostic modules to continuously verify terminal voltage stability. Mechanical design supports standard mounting on TS-35/7.5 and TS-35/15 symmetrical DIN rails. Rated for operational temperatures from -20°C to +70°C and up to 90% non-condensing relative humidity, it excels in smart manufacturing, SCADA edge computing, robotics, and industrial automation distributed panels.
| Project | Tehnical index | ||||
| Output | DC voltage | 5V | 12V | 24V | 48V |
| Rated current | 20A | 8.3A | 4.16A | 2.08A | |
| Rated power | 100W | 100W | 100W | 100W | |
| Ripple and noise ① | <80mV | <120mV | <150mV | <200mV | |
| Voltage accuracy | ±2% | ±1% | ±1% | ±1% | |
| Output voltage regulation range | ±10% | ||||
| Load adjustment rate | ±1.5% | ±1% | ±1% | ±1% | |
| Linear adjustment rate | ±1% | ||||
| Input | Voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | |||
| Efficiency(typical) ② | >78% | >86% | >88% | >87% | |
| Working current | <1.8A 110VAC <1A 220VAC | ||||
| Impulse current | 110VAC 35A, 220VAC 70A | ||||
| Start,rise hold time | 500ms、30ms、25ms :110VAC 500ms、30ms、120ms :220VAC | ||||
| Protect | Overload protection | 105%-150% type:protection mode:automatic recovery after belching mode abnormal conditions are removed | |||
| Overload protection | When the output voltage is more than 135%,close the abnormanl output condition and restart it for recovery | ||||
| Environ mental science | Working current | -20℃~+70℃;20%~90RH | |||
| Storage temperature and humidity | -40℃~+85℃;10%~95RH | ||||
| Safety regulations | Withstand voltage | Input output:3KVAC input ground:1.5KVAC outpu ground :0.5KVAC for 1 minute | |||
| Isolation resistance | Input output,input shell,output shell :500VDC/100MΩ | ||||
| Sther | Size | 40*90*100mm | |||
| Net weight/gross weight | 420/450g | ||||
| Remark | ①Ripple and noise measurement method: use a 12″ twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at a bandwidth of 20MHz. ②The efficiency is at an input voltage of 230VAC, rated load, and an ambient temperature of 25°C Under test. Accuracy: including setting error, linear adjustment rate and load adjustment rate. Linear adjustment rate test method: from low voltage to high voltage under rated load test load adjustment rate test method: from 0%-100% rated load. The start-up time is measured in the cold start state. Rapid and frequent switching of the machine may increase the start-up time. When the operating altitude is higher than 2000 meters, the operating environment temperature needs to be lowered by 5°C/1000 meters. | ||||