Your Cart
We use cookies 🍪
We use cookies and other similar technologies to improve your browsing experience and the functionality of our site. Learn more in our Privacy Policy.

Industrial Switching Power Supply Series (50W - 600W)

Industrial Switching Power Supply Series (50W - 600W)
Industrial Switching Power Supply Series (50W - 600W)
Industrial Switching Power Supply Series (50W - 600W)
Industrial Switching Power Supply Series (50W - 600W)
Industrial Switching Power Supply Series (50W - 600W)
Industrial Switching Power Supply Series (50W - 600W)
Industrial Switching Power Supply Series (50W - 600W)
Industrial Switching Power Supply Series (50W - 600W)
Industrial Switching Power Supply Series (50W - 600W)
Industrial Switching Power Supply Series (50W - 600W)
Industrial Switching Power Supply Series (50W - 600W)
Industrial Switching Power Supply Series (50W - 600W)
Industrial Switching Power Supply Series (50W - 600W)
Industrial Switching Power Supply Series (50W - 600W)
New
Industrial Switching Power Supply Series (50W - 600W)
Industrial Switching Power Supply Series (50W - 600W)
Industrial Switching Power Supply Series (50W - 600W)
Industrial Switching Power Supply Series (50W - 600W)
Industrial Switching Power Supply Series (50W - 600W)
Industrial Switching Power Supply Series (50W - 600W)
Industrial Switching Power Supply Series (50W - 600W)
Industrial Switching Power Supply Series (50W - 600W)
Industrial Switching Power Supply Series (50W - 600W)
Industrial Switching Power Supply Series (50W - 600W)
Industrial Switching Power Supply Series (50W - 600W)
Industrial Switching Power Supply Series (50W - 600W)
Industrial Switching Power Supply Series (50W - 600W)
Industrial Switching Power Supply Series (50W - 600W)

Product Overview
Engineered for industrial automation, high-power LED installations, and precision embedded systems, the BDN Multi-Range AC-DC Regulated Switching Power Supply series delivers high-efficiency power conversion across 50W to 600W configurations. Designed to operate reliably under variable mains electrical conditions, this robust power platform features wide AC dual-voltage tolerance with low ripple, low noise, and integrated line filtering.

Key Specifications & Variant Matrix
Input Voltage Range: 100-240V AC universal or 110V/220V AC ±15% manual switchable selection (50/60Hz). Available DC Output Configurations: 5V DC at 10A (50W), 12V DC at 10A (120W), 12V DC at 15A (180W), and 12V DC at 50A (600W). Load Regulation: ±1.0%. Voltage Tolerance: ±1.0%. High conversion efficiency up to 88% nominal.

Available List of items

DC Output: 5V 10A (50W)

12V 10A (120W)

12V 15A (180W)

12V 50A (600W)

Integrated Hardware Protection
Each unit incorporates comprehensive multi-stage circuit defense including active output over-voltage clamping (OVP), foldback over-current protection (OCP), automatic-recovery short-circuit protection (SCP), and input surge suppression. Visual operational status is continuously indicated via a primary output LED diagnostic indicator.

Thermal & Mechanical Architecture
Constructed inside a perforated, corrosion-resistant aluminum mesh chassis optimized for passive convection airflow and rapid thermal dissipation. The heavy-duty terminal block array features protective safety covers and screw-clamp retention rated for continuous duty in demanding industrial and telecommunications deployments.

Target Applications
Ideal for high-density LED signage, machine vision systems, 3D printers, CNC control boards, industrial PLCs, telecommunication relays, and modular edge computing power distribution racks.

PSC-60 UPS/Charge Function Switching Power Supply
Project Technical indicators
Model PSC-60-12 PSC-60-24
Output DC voltage CH1:13.8V CH2:13.8V CH1:27.6V CH2 :27.6V
Output voltage
tolerance
±1% ——– ±1% ——–
Rated current 3.5A 1A(Charge) 1.5A 0.7A(Charge)
Ripple and noise 150mVp-p ——- 200mVp-p ——–
rated power 60W 60W
Output current range 0-4.5A ——– 0-4.5A ——-
DC voltage adjustable
range
CH1:11.3-14.9V CH1:21.3-29.8V
Start,rise,hold time 600ms、50ms、80ms:230VAC ,
1200ms、50ms、16ms:115VAC
600ms、50ms、80ms:230VAC,
1200ms、50ms、16ms:115VAC
Input voltage range 90-264VAC 47-63HZ;135VDC~370VDC
Efficiency(typical) >88% >88% >88% >88%
Working current 115VAC<1.8A ,230VAC <0.9A
pulse current 110VAC 25A,230VAC 40A
Start,rise,hold time 100ms、30ms、21ms:110VAC ,100ms、30ms、100ms:
220VAC
Protect Overload protection When the output rated power is>105%-115%:Protection mode:
hiccup mode,it can automatically recover after the abnormal conditions are removed.
Battery low voltage
protection
9.5~10.3V,Protection mode,cut off output 19~20.5V,Protection mode,cut off output
Environment Working temperature,
humidity
-20C~+60°℃,20%~90RH
Storage temperature
and humidity
-20C~+85℃,10%~95RH
Function UPS Long-term online float charging of the battery,high charging
efficiency,battery fullness can be as high as 97% or more
Automatically stops when fully charged to prevent battery
overcharging and effectively extend battery life
Automatic mains/battery switching,no switching time,no need for human supervision.
Cold start function,when there is no mains power,the UPS can be started directly with the battery to meet the user’s emergency
needs
Safety
regulations
Protection mode,cut
off output
Input and output:1.5KVAC,1 minute
solation resistor Input and output,input shell,output shell:500VDC/100MQ
Other size 129*97*30mm
Net weight/gross weight 0.38KG/0.42KG
PSC-100 UPS/Charge Function Switching Power Supply
Project Technical indicators
Model PSC-100-12 PSC-100-24
Output DC voltage CH1:13.8V CH2:13.8V CH1:27.6V CH2 :27.6V
Output voltage
tolerance
±1% ——– ±1% ——–
Rated current 5A 2A(Charge) 2.5A 1A(Charge)
Ripple and noise 150mVp-p ——- 200mVp-p ——–
rated power 100W 100W
Output current range 0-7A ——– 0-3.5A ——-
DC voltage adjustable
range
CH1:11.3-14.9V CH1:21.3-29.8V
Start,rise,hold time 600ms、50ms、80ms:230VAC ,
1200ms、50ms、16ms:115VAC
600ms、50ms、80ms:230VAC,
1200ms、50ms、16ms:115VAC
Input voltage range 90-264VAC 47-63HZ;135VDC~370VDC
Efficiency(typical) >87% >87% >87% >87%
Working current 115VAC<2.4A ,230VAC <1.2A
pulse current 110VAC 30A,230VAC 50A
Start,rise,hold time 100ms、30ms、21ms:110VAC ,100ms、30ms、100ms:
220VAC
Protect Overload protection When the output rated power is>105%-115%:Protection mode:
hiccup mode,it can automatically recover after the abnormal conditions are removed.
Battery low voltage
protection
9.5~10.3V,Protection mode,cut off output 19~20.5V,Protection mode,cut off output
Environment Working temperature,
humidity
-20C~+60°℃,20%~90RH
Storage temperature
and humidity
-20C~+85℃,10%~95RH
Function UPS Long-term online float charging of the battery,high charging
efficiency,battery fullness can be as high as 97% or more
Automatically stops when fully charged to prevent battery
overcharging and effectively extend battery life
Automatic mains/battery switching,no switching time,no need for human supervision.
Cold start function,when there is no mains power,the UPS can be started directly with the battery to meet the user’s emergency
needs
Safety
regulations
Protection mode,cut
off output
Input and output:1.5KVAC,1 minute
solation resistor Input and output,input shell,output shell:500VDC/100MQ
Other size 129*97*30mm
Net weight/gross weight 0.38KG/0.42KG
PSC-150 UPS/Charge Function Switching Power Supply
Project Technical indicators
Model PSC-150-12 PSC-150-24
Output DC voltage CH1:13.8V CH2:13.8V CH1:27.6V CH2 :27.6V
Output voltage
tolerance
±1% ——– ±1% ——–
Rated current 7.5A 3A(Charge) 4A 1.5A(Charge)
Ripple and noise 150mVp-p ——- 200mVp-p ——–
rated power 150W 152W
Output current range 0-10.5A ——– 0-5.5A ——-
DC voltage adjustable
range
CH1:11.3-14.9V CH1:21.3-29.8V
Start,rise,hold time 600ms、50ms、80ms:230VAC ,
1200ms、50ms、16ms:115VAC
600ms、50ms、80ms:230VAC,
1200ms、50ms、16ms:115VAC
Input voltage range 90-264VAC 47-63HZ;135VDC~370VDC
Efficiency(typical) >87% >87% >89% >89%
Working current 115VAC<3.2A ,230VAC <1.6A
pulse current 110VAC 30A,230VAC 50A
Protect Overload protection When the output rated power is>105%-115%:Protection mode:
hiccup mode,it can automatically recover after the abnormal conditions are removed.
Battery low voltage
protection
9.5~10.3V,Protection mode,cut off output 19~20.5V,Protection mode,cut off output
Environment Working temperature,
humidity
-20C~+60°℃,20%~90RH
Storage temperature
and humidity
-20C~+85℃,10%~95RH
Function UPS Long-term online float charging of the battery,high charging
efficiency,battery fullness can be as high as 97% or more
Automatically stops when fully charged to prevent battery
overcharging and effectively extend battery life
Automatic mains/battery switching,no switching time,no need for human supervision.
Cold start function,when there is no mains power,the UPS can be started directly with the battery to meet the user’s emergency
needs
Safety
regulations
Protection mode,cut
off output
Input and output:1.5KVAC,1 minute
solation resistor Input and output,input shell,output shell:500VDC/100MQ
Other size 159*97*30mm
Net weight/gross weight 0.47KG/0.55KG
PSC-250 UPS/Charge Function Switching Power Supply
Project Technical indicators
Model PSC-250-12 PSC-250-24
Output DC voltage CH1:13.8V CH2:13.8V CH1:27.6V CH2 :27.6V
Output voltage
tolerance
±1% ——– ±1% ——–
Rated current 14.5A 3.5A(Charge) 6.5A 2.5A(Charge)
Ripple and noise 150mVp-p ——- 200mVp-p ——–
rated power 250W 250W
Output current range 0-18A ——– 0-9A ——-
DC voltage adjustable
range
CH1:11.3-14.9V CH1:21.3-29.8V
Start,rise,hold time 600ms、50ms、80ms:230VAC ,
1200ms、50ms、16ms:115VAC
600ms、50ms、80ms:230VAC,
1200ms、50ms、16ms:115VAC
Input voltage range 90-264VAC 47-63HZ;135VDC~370VDC
Efficiency(typical) >87% >87% >89% >89%
Working current 115VAC<4.5A ,230VAC <2.5A
pulse current 110VAC 45A,230VAC 55A
Protect Overload protection When the output rated power is>105%-115%:Protection mode:
hiccup mode,it can automatically recover after the abnormal conditions are removed.
Battery low voltage
protection
9.5~10.3V,Protection mode,cut off output 19~20.5V,Protection mode,cut off output
Environment Working temperature,
humidity
-20C~+60°℃,20%~90RH
Storage temperature
and humidity
-20C~+85℃,10%~95RH
Function UPS Long-term online float charging of the battery,high charging
efficiency,battery fullness can be as high as 97% or more
Automatically stops when fully charged to prevent battery
overcharging and effectively extend battery life
Automatic mains/battery switching,no switching time,no need for human supervision.
Cold start function,when there is no mains power,the UPS can be started directly with the battery to meet the user’s emergency
needs
Safety
regulations
Protection mode,cut
off output
Input and output:1.5KVAC,1 minute
solation resistor Input and output,input shell,output shell:500VDC/100MQ
Other size 215*115*30mm
Net weight/gross weight 0.75KG/0.82KG
PSC-350 UPS/Charge Function Switching Power Supply
Project Technical indicators
Model PSC-350-12 PSC-350-24
Output DC voltage CH1:13.8V CH2:13.8V CH1:27.6V CH2 :27.6V
Output voltage
tolerance
±1% ——– ±1% ——–
Rated current 20A 5A(Charge) 10A 2.5A(Charge)
Ripple and noise 150mVp-p ——- 200mVp-p ——–
rated power 345W 350W
Output current range 0-18A ——– 0-9A ——-
DC voltage adjustable
range
CH1:11.3-14.9V CH1:21.3-29.8V
Start,rise,hold time 600ms、50ms、80ms:230VAC ,
1200ms、50ms、16ms:115VAC
600ms、50ms、80ms:230VAC,
1200ms、50ms、16ms:115VAC
Input voltage range 90-264VAC 47-63HZ;135VDC~370VDC
Efficiency(typical) >87% >87% >89% >89%
Working current 115VAC<6.5A ,230VAC <3.5A
pulse current 110VAC 45A,230VAC 55A
Protect Overload protection When the output rated power is>105%-115%:Protection mode:
hiccup mode,it can automatically recover after the abnormal conditions are removed.
Battery low voltage
protection
9.5~10.3V,Protection mode,cut off output 19~20.5V,Protection mode,cut off output
Environment Working temperature,
humidity
-20C~+60°℃,20%~90RH
Storage temperature
and humidity
-20C~+85℃,10%~95RH
Function UPS Long-term online float charging of the battery,high charging
efficiency,battery fullness can be as high as 97% or more
Automatically stops when fully charged to prevent battery
overcharging and effectively extend battery life
Automatic mains/battery switching,no switching time,no need for human supervision.
Cold start function,when there is no mains power,the UPS can be started directly with the battery to meet the user’s emergency
needs
Safety
regulations
Protection mode,cut
off output
Input and output:1.5KVAC,1 minute
solation resistor Input and output,input shell,output shell:500VDC/100MQ
Other size 215*115*30mm
Net weight/gross weight 0.85KG/0.95KG